Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
ad8306ar
Αποστρατιωτικοποίηση:
Yes - DEMIL/MLI
Πληροφορίες ανταλλακτικού
5 mhz-400 mhz 100 db high precision limiting-logarithmic amplifier
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Linear Microcircuit
Κωδικός ονόματος στοιχείου:
31778
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 5.800 inches and 6.200 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
Between 1.350 inches and 1.750 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
Between 3.800 inches and 4.000 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
Between 9.800 inches and 10.000 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
Between 1.100 inches and 1.650 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-40.0/+85.0 degrees celsius
MRC:
The minimum and maximum temperatures at which an item can be stored without detrimental effect.AFJQ
Storage Tempurature Range:
-65.0/+150.0 degrees celsius
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Receivers for frequency and phase modulation; very wide range if and rf power measurement; receiver signal strength indication (rssi); low cost radar and sonar signal processing; instrumentation, network and spectrum analyzers
MRC:
The basic purpose and number of functions of the device,modified by its intended use.CSSL
Design Function And Quantity:
1 amplifier, log
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Complete, fully calibrated log-limiting if amplifier; 100 db dynamic range, -91 dbv to +9 dbv; stable rssi scaling over temperature and supplies, 20 mv/db slope, -95 dbm intercept +/-0.4 db rssi linearity up to 200 mhz; programmable limiter gain and output current, differential outputs to 10 ma, 2.4 v p-p, gain 90 db, bandwith 400 mhz, constant phase (typical +/-56 ps delay skew); single supply of +2.7 v to +6.5 v at 16 ma typical; fully differential inputs; 500 ns power up time