Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
atv251
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Power Supply
Κωδικός ονόματος στοιχείου:
00740
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
6.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.620 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.000 inches
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Hole
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single single operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
100.0 ac volts single operating power rqmt and 240.0 ac volts single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
-12.0 dc volts 3rd power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
12.0 dc volts 2nd power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
5.0 dc volts 1st power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz single operating power rqmt and 440.0 hertz single operating power rqmt
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
0.4 dc amperes 2nd power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
0.4 dc amperes 3rd power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
2.0 dc amperes 1st power output
MRC:
The maximum alternating current voltage variation which may be present on the direct current output voltage level.CWGZ
Ripple Voltage At Full Load:
2.0 millivolts rms 1st power output
MRC:
The maximum alternating current voltage variation which may be present on the direct current output voltage level.CWGZ
Ripple Voltage At Full Load:
2.0 millivolts rms 2nd power output
MRC:
The maximum alternating current voltage variation which may be present on the direct current output voltage level.CWGZ
Ripple Voltage At Full Load:
2.0 millivolts rms 3rd power output