Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
c8001-1
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Electrical Solenoid
Κωδικός ονόματος στοιχείου:
00310
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
1.688 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
1.688 inches
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Steel
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the case.ADTY
Case Surface Treatment:
Cadmium
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Any acceptable
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
0.169 inches
MRC:
The number of magnetic coils provided.APAF
Magnetic Coil Quantity:
1
MRC:
The voltage rating at which the item is designed to operate,expressed in volts.ASXH
Voltage Rating In Volts:
28.0 dc
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 unthreaded hole
MRC:
The amount of current for which the item is designed.AXNP
Current Rating:
8.400 amperes
MRC:
The movement of the actuator when force is applied.CNXT
Actuator Stroke Type:
Rotary
MRC:
Indicates the type of means provided for connection of the power takeoff.CNXX
Power Takeoff Connection Type:
Ratchet
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
Four position rectangular
MRC:
The direction in which an item is designed to rotate,when viewed axially and the angular degree of travel from the de-energized to the energized position.CSQY
Rotation Direction And Energizing Stroke In Angular Deg:
45.0 counterclockwise
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 wire lead