Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
co-19lge120-220sx9sj0830
Μονάδα μέτρησης:
No qup FT
Πληροφορίες ανταλλακτικού
Sixth grouping arrangement tenth and eleventh conductor through tenth grouping arrangement eigh-teenth and nine-teenth conductor
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Electrical Special Purpose Cable
Κωδικός ονόματος στοιχείου:
16488
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-40.0 degrees celsius and 75.0 degrees celsius
MRC:
The length of a straight line which passes through the center of a cross section,and terminates at the outside circumference.ADVL
Cross Section Outside Diameter:
0.830 inches
MRC:
The number of electrical conductors included on the item.AMQN
Conductor Quantity:
19
MRC:
The number of strands per conductor.BLNZ
Strand Quantity Per Conductor:
41 all conductors
MRC:
The fabricated form of the conductor.CXCW
Conductor Form:
Stranded all conductors
MRC:
The designation used to describe the round stranded or round solid conductor size.CXDC
Round Conductor Size:
20 awg all conductors
MRC:
The american wire gage size of the individual strands of wire used in each stranded conductor.CXDG
Strand Awg Size Per Conductor:
36 all conductors
MRC:
The arrangement and number of arrangements of the conductors.CXDQ
Conductor Arrangement And Quantity:
1 singles and 9 twisted pair
MRC:
Indicates the type and number of conductor arrangements within groups.CXDY
Conductor Grouping Arrangement Type And Quantity:
1 singles all groups and 1 twisted pair all groups and 1 twisted pair all groups and 1 twisted pair all groups and 1 twisted pair all groups and 1 twisted pair all groups and 1 twisted pair all groups and 1 twisted pair all groups and 1 twisted pair all groups and 1 twisted pair all groups
MRC:
The identification of the conductors within a group.CXFG
Conductor Sequence Within Groups:
Eighth conductor fifth group and ninth conductor fifth group
MRC:
The identification of the conductors within a group.CXFG
Conductor Sequence Within Groups:
First conductor first group
MRC:
The identification of the conductors within a group.CXFG
Conductor Sequence Within Groups:
Fourth conductor third group and fifth conductor third group
MRC:
The identification of the conductors within a group.CXFG
Conductor Sequence Within Groups:
Second conductor second group and third conductor second group
MRC:
The identification of the conductors within a group.CXFG
Conductor Sequence Within Groups:
Sixth conductor fourth group and seventh conductor fourth group
MRC:
The maximum sustained voltage that can be safely applied to the item without risking failure or damage.CXFK
Voltage Rating:
300.0 root mean square (rms) operating voltage all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper core conductor all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Rubber butadiene-styrene class sbr 1st position primary insulation all conductors or rubber 1st position primary insulation all conductors
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Mil-i-3930, type is or type ih military specification single material response 1st position primary insulation all conductors
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Qq-w-343, soft federal specification single material response core conductor all conductors
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Tin core conductor all conductors
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as type,class,grade,and the like,that identifies the surface treatment material.STDC
Surface Treatment Specification:
Astm b33-63 assn standard single treatment response core conductor all conductors