Αριθμός ανταλλακτικού:
d161700tj
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Induct Wire Wound Fixed Resistor
Κωδικός ονόματος στοιχείου:
37403
MRC:
A constant that represents the proportionate change in resistance caused by a change in temperature,expressed in parts per million change per degree celsius.AAPE
Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius:
-10.0/+10.0
MRC:
A measure of the opposition to the flow of electrical current.AAPP
Electrical Resistance:
6.905 kilohms
MRC:
The limits of permissible variation in the electrical resistance value of an item from its rated value,expressed in percent.AAPQ
Resistance Tolerance In Percent:
-1.000/+1.000
MRC:
The limits of permissible variation in the electrical resistance value of an item from its rated value,expressed in percent.AAPQ
Resistance Tolerance In Percent:
-1.000 to 1.000
MRC:
The number of fixed terminals at points between the end terminals that provide connection to intermediate values of the total value.AAPR
Fixed Tap Quantity:
1
MRC:
The ambient temperature of the medium surrounding an item at which it can be operated continuously at full rated power,expressed in degrees celsius.AAQF
Ambient Tempurature In Deg Celsius At Full Rated Power:
25.0
MRC:
The ambient temperature at which the power dissipation of an item is operated to zero percent of the full rated power,expressed in degrees celsius.AAQG
Ambient Tempurature In Deg Celsius At Zero Percent Rated Power:
120.0
MRC:
The maximum and minimum temperatures to which the temperature coefficient applies,expressed in degrees celsius.AAQH
Tempurature Range Of Tempurature Coefficient In Deg Celsius:
-55.0/+120.0
MRC:
The maximum and minimum temperatures to which the temperature coefficient applies,expressed in degrees celsius.AAQH
Tempurature Range Of Tempurature Coefficient In Deg Celsius:
-55.0 to 120.0
MRC:
The means provided to coat,cover,or protect the item.AAQZ
Inclosure Method:
Uninclosed
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Threaded stud
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
1.188 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
3.500 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
1.656 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
0.375 inches
MRC:
The maximum amount of electrical energy that can be expended by an item,expressed in watts.AEFB
Power Dissipation Rating In Watts:
5.100 free air
MRC:
A measure of the nominal opposition to the flow of electric current through the section.CQFD
Section Resistance:
3.452 kilohms
MRC:
A measure of the nominal opposition to the flow of electric current through the section.CQFD
Section Resistance:
Unable to decode
MRC:
Indicates the type of terminal/s/ on the fixed tap/s/ that is provided for electrical connection.CQFK
Fixed Tap Terminal Type:
Threaded stud
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Terminals one end