Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
e-520
Αποστρατιωτικοποίηση:
Yes - DEMIL/MLI
Πληροφορίες ανταλλακτικού
External and internal detector tubes; 5 ranges 0-0.2, 0-2, 0-20, 0-200, 0-2000 mr/hr; splashproof, dustproof, operating temp range m40 tp p140 degrees f; with hp-177c external probe
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Radiacmeter
Κωδικός ονόματος στοιχείου:
07833
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
8.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
6.750 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.000 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
The means of attaching the item.ADJH
Mounting Method:
Portable
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Metal
MRC:
An indication of whether or not a container from which the item is completely removable in normal operable condition is provided.AFJU
Carrying Case:
Not provided
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Included
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Meter
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
Gamma rays detects
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
Beta rays detects
MRC:
Indicates the type of detecting element included.AMRX
Detecting Element Type:
Geiger tube
MRC:
An indication of whether or not the item is portable.APCB
Portability:
Portable
MRC:
The minimum and maximum amount of radiation detected per hour.APPJ
Radiation Range Per Hour:
+0.0/+2000.0 milliroentgens
MRC:
The minimum and maximum number of single responses per minute.APPK
Count Range Per Minute:
+0.0/+28000.0
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
Not rated
MRC:
The value of electrical potential to which an item will respond.APPP
Input Sensitivity Voltage Rating:
10.0 millivolts
MRC:
An indication of the energy dependence rating of the item.APPQ
Energy Dependence Rating:
Not rated
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
3.0 dc
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
3.0