Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
g319244-1
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Diode Semiconductor Device
Κωδικός ονόματος στοιχείου:
20589
MRC:
The element,compound,or mixture of which the inclosure is fabricated,excluding any surface treatment.ABBH
Inclosure Material:
Glass
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 0.190 inches and 0.260 inches
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
1.100 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
Between 0.125 inches and 0.250 inches
MRC:
The specific purpose for which the item is designed.AFZC
Function For Which Designed:
Rectifier
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Milstar
MRC:
The means of attaching the item.AXGY
Mounting Method:
Terminal
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Hermetically sealed case
MRC:
The chemical compound or mechanical mixture properties of which the semiconductor is fabricated.CTMZ
Semiconductor Material:
Silicon
MRC:
The value of the voltage that may be applied,expressed in volts,and the symbol used to identify the specific electrical characteristic.CTQN
Voltage Rating In Volts Per Characteristic:
800.0 repetitive peak reverse voltage and 800.0 reverse voltage, instantaneous and 560.0 reverse voltage, total rms
MRC:
The level of electrical flow and the symbol used to identify the specific electrical characteristic.CTQX
Current Rating Per Characteristic:
75.00 amperes forward current, average preset and 18.00 amperes forward current, average blank and 3.00 amperes forward current, average absolute
MRC:
The maximum temperature at which the item is designed to operate at each measurement point.CTSG
Maximum Operating Tempurature Per Measurement Point:
175.0 degrees celsius ambient air
MRC:
Test conditions and ratings,or environmental and performance requirements that are different,more critical,or more specific than those specified in a governing test data document.SPCL
Special Test Features:
Selected and tested for the milstar lrip program
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
49956-g494565 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 uninsulated wire lead