Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
ggt406type2classbstyle2m0delb
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Time Stamp
Κωδικός ονόματος στοιχείου:
02672
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Desk
MRC:
Indicates the type of printout the item will record.ARCS
Recorder Printout Type:
Day of month and year and hour, 0 to 23
MRC:
The position in which the item will record or print.ARCT
Recording Position:
Horizontal
MRC:
The number of colors the item is designed to print.ARCW
Printed Color Quantity:
1
MRC:
Indicates the type of mechanism that positions the document.ARCX
Document Positioning Type:
Manual document
MRC:
The means used to actuate the printing mechanism.ARCY
Printing Mechanism Actuation Method:
Automatic
MRC:
Indicates the type of primary circuit drive.ARCZ
Primary Circuit Drive Type:
Synchronous motor
MRC:
The total electrical voltage of the primary circuit.ARDA
Primary Circuit Voltage:
110.0 ac
MRC:
The cycles per second /hertz/ of the alternating current.ARDB
Primary Circuit Frequency:
60.0
MRC:
The number of alternating current phases of the primary circuit.ARDC
Primary Circuit Phase:
Single
MRC:
The number of beats /pulses/ that occur per second in the primary circuit.ARDD
Err Default:
Err default
MRC:
The number of beats /pulses/ that occur per second in the primary circuit.ARDD
Primary Circuit Beat Quantity:
60.0
MRC:
Indicates the type of supervising circuit drive.ARDE
Err Default:
Err default
MRC:
Indicates the type of supervising circuit drive.ARDE
Supervising Circuit Drive Type:
Synchronous motor
MRC:
The total electrical voltage of the supervising circuit.ARDF
Err Default:
Err default and err default
MRC:
The total electrical voltage of the supervising circuit.ARDF
Supervising Circuit Voltage:
Between 110.0 ac and 120.0 ac
MRC:
The cycles per second /hertz/ of the alternating current.ARDG
Err Default:
Err default
MRC:
The cycles per second /hertz/ of the alternating current.ARDG
Supervising Circuit Frequency:
60.0
MRC:
The number of alternating current phases of the supervising circuit.ARDH
Err Default:
Err default
MRC:
The number of alternating current phases of the supervising circuit.ARDH
Supervising Circuit Phase:
Single
MRC:
The number of beats /pulses/ that occur per second in the supervising circuit.ARDJ
Err Default:
Err default
MRC:
The number of beats /pulses/ that occur per second in the supervising circuit.ARDJ
Supervising Circuit Beat Quantity:
60.0
MRC:
The number of wires contained in the supervising circuit.ARDK
Err Default:
Err default
MRC:
The number of wires contained in the supervising circuit.ARDK
Supervising Circuit Wire Quantity:
2