Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
kc84082-001
Πληροφορίες ανταλλακτικού
Heater controller
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Electrical/electroni Control Box
Κωδικός ονόματος στοιχείου:
42426
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
200.0 ac and 28.0 dc
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Sh-2g helicopter
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The position of the terminal/s/ for making connection to an item.APXH
Terminal Location:
One side
MRC:
The minimum and maximum operating limits of the item.ASXT
Operating Range:
243 to 258 degrees f
MRC:
The source of power which drives the item.ATJK
Power Source:
External
MRC:
The means of attaching the item.AXGY
Mounting Method:
Base and flange
MRC:
The maximum rated power that an item can safely consume or provide,measured in watts.AZQH
Maximum Wattage Rating In Watts:
10000.0
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Power light
MRC:
Indicates the type and number of terminals for providing electrical connection.CCFF
Terminal Type And Quantity:
2 connector plug
MRC:
A maximum measurement of the longest dimension of an item,in distinction from width.CHQP
Maximumlength:
7.990 inches
MRC:
The maximum measurement taken at right angles to the length of an item,in distinction from thickness.CHQQ
Maximumwidth:
5.750 inches
MRC:
The maximum distance measured in a straight line from the bottom to the top of an item.CHQR
Maximumheight:
6.510 inches
MRC:
The intelligence data the item is capable of handling.CKQY
Intelligence Data Handling Capability:
Air temperature receiving automatic and heater on transmitting automatic
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
One connector plug is for 28 vdc and one is 115/200 vac; bottom side of mounting flange is case bonding pad; four mounting holes 0.221 inch dia. Are located near end of each protruding flange
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
400.0
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Used to control anti-icer forward fairing and anti-icers upper and lower aft fairing