Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
mil-h-12322
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Steam-hot Water Hea Water Heater
Κωδικός ονόματος στοιχείου:
13711
MRC:
The maximum pressure at which an item is designed to operate.AAJJ
Maximum Operating Pressure:
85.0 pounds per square inch
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
96.000 inches
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the outside circumference.ABKV
Outside Diameter:
48.000 inches
MRC:
The installed position for which the item is designed.ADSM
Mounting Position:
Vertical
MRC:
Items furnished as accessories which are not specified elsewhere.AFJH
Furnished Items:
Breaker, vacuum, strainer, 3/4 in., strainer, 2 in., thermometer, angle type, range 40 degrees f to 240 degrees f, trap, bucket, inverted, 3/4 in., valve, check, valve, drain, 2 in., valve, relief, temp and press, valve, temp regulating
MRC:
The rated heating capacity of the item per hour.AMHR
Heating Capacity Per Hour:
20.000 gallons
MRC:
Indicates the capacity of the tank.AMKA
Tank Capacity:
750.0 gallons
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the water inlet connection.AMLL
Water Inlet Connection Thread Size And Series/type Designator:
4 in.-8 npt
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the water outlet connection.AMLM
Water Outlet Connection Thread Size And Series/type Designator:
2 in.-11-1/2 npt
MRC:
The number of water inlet connections.AMLQ
Water Inlet Connection Quantity:
1
MRC:
The number of water outlet connections.AMLR
Water Outlet Connection Quantity:
1
MRC:
The maximum pressure at which the heating coil is designed to operate.AMRE
Heating Coil Maximum Operating Pressure:
150.0 pounds per square inch
MRC:
An indication of the surface area of a heating coil.AMRF
Heating Coil Surface Area:
38.000 square feet
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the heating coil inlet connection.AMRG
Err Default:
Err default
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the heating coil inlet connection.AMRG
Heating Coil Inlet Connection Thread Size And Series/type Designator:
4 in.-8 npt
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the heating coil outlet connection.AMRH
Err Default:
Err default
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the heating coil outlet connection.AMRH
Heating Coil Outlet Connection Thread Size And Series/type Designator:
2 in.-11-1/2 npt
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Steel, corrosion resisting
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Stainless steel
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Paint
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects a surface.SURF
Surface Treatment:
Painted
MRC:
The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
Specification Or Standard:
1 class