MRC:
A recording of the physical,functional,and performance characteristics for an item of supply.TEXT
General Description:
Inlet operating conditions, 20 cu ft per hr of compressed air as specified, 2500 to 3000 psi gage, 105 degrees f maximum temp; delivered air or gas conditions, 40 degrees f to m60 degrees f dew point, 155 degrees f maximum temp; activated alumina, 2 absorber beds; heater data, ac, 440 v, 60 cycles, 3 phase, semiautomatic operation
MRC:
The technical differentiating characteristic/s/ of an item of supply which depart/s/ from the text of a specification or a standard in that it represents a selection of characteristics stated in the specification or standard as being optional,or a variation from one or more of the stated characteristics,or an additional characteristic not stated in the specification or standard.ZZZW
Departure From Cited Document:
As modified by mil-d-17847 20 cu ft per hr of compressed air as specified, delivered air or gas conditions