Αριθμός ανταλλακτικού:
mobiflexw-tablepercepth
Αποστρατιωτικοποίηση:
Yes - DEMIL/MLI
Πληροφορίες ανταλλακτικού
X-ray app rad med mobile 250ma at 100pkv 115-230 volt 50-60hz ac
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Med Radiographic X-ray Apparatus
Κωδικός ονόματος στοιχείου:
06320
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Mobile
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
Installation, calibration, maintenance, operator manual sets 2; field use bucky table 1
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
75.0
MRC:
Indicates the design type of the item.APGF
Design Type:
Mobile
MRC:
The means used to operate the item.APHE
Operation Method:
Manual
MRC:
Indicates the type of control.AQZF
Control Type:
Cabinet
MRC:
The number of tubes included on the item.ARNF
Tube Quantity:
1
MRC:
The value of electrical energy for which the item is rated.ARQE
Electric Power Rating:
25000.0 watts
MRC:
Indicates the type of tube provided.AWGH
Tube Type:
Double focus, rotating anode radiographic
MRC:
Indicates the type of table provided.BNBB
Table Type:
Nontilting
MRC:
Indicates the type of rectification provided.BPKZ
Rectification Type:
Full-wave
MRC:
The means of cooling used to maintain the required operating temperature of the tube.CLPG
Tube Cooling Method:
Air
MRC:
Indicates the type of mount utilized to support the tube.CLPH
Tube Mounting Type:
Tube stand
MRC:
Indicates the type of mount utilized to support the tube stand.CLPR
Tube Stand Mounting Type:
Spring counter-balance
MRC:
Indicates the type of radiographic timer provided.CLPX
Radiographic Timer Type:
Exposure
MRC:
The means used for rectifying the transformer.CLQD
Transformer Rectification Method:
Solid state
MRC:
The power output for which the transformer is rated.CLQF
Transformer Output Capacity:
250 ma at 100 kv peak and 200 ma at 125 kv peak
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
115.0 and 230.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
50.0 or 60.0
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
C/o collimeter, control unit, table, transformer, and tube stand