Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
n285173-1
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Delay Line
Κωδικός ονόματος στοιχείου:
06373
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Rectangular, front connection
MRC:
The length of a straight line which passes through the center of a hole,and terminates at the circumference.AAUB
Hole Diameter:
0.173 inches
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
2.470 inches
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Not rated
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
6.090 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
2.120 inches
MRC:
The number of individual sections included in the item.AFBH
Individual Section Quantity:
4
MRC:
The longest distance between mounting centers parallel to the horizontal plane.AFDS
Longest Horizontal Distance Between Mounting Centers:
5.120 inches
MRC:
The longest distance between mounting centers parallel to the vertical plane.AFDV
Longest Vertical Distance Between Mounting Centers:
1.000 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
Not rated
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
4
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
Not rated
MRC:
The total oppositon (resistive and reactive) which the item offers to the input flow of alternating current.ANSL
Input Impedance Rating:
1.000 kilohms
MRC:
The total opposition (resistive and reactive) which the item offers to the output flow of alternating current.ANSR
Output Impedance Rating:
Not rated
MRC:
The differences between limiting frequencies of a frequency band.APQL
Frequency Bandwidth:
Not rated
MRC:
A measurement between specified points on a body in distinction from height.ARBR
Body Depth:
2.050 inches
MRC:
The facility for mounting the item.AZGM
Mounting Facility:
Unthreaded hole
MRC:
The style designation indicating the configuration that most nearly corresponds to the arrangement of the mounting provision(s).BBBW
Mounting Provision Arrangement Style:
Four position rectangular
MRC:
The decrease in strength of an electrical impulse,expressed in decibels.BHTH
Attenuation In Decibels:
Not rated
MRC:
The means by which the signal is delayed.BZWM
Signal Delay Method:
Lumped constant
MRC:
The time delay of each section of an item.CCDQ
Section Delay Time:
0.100 microseconds 1st section err-100
MRC:
The time delay of each section of an item.CCDQ
Section Delay Time:
0.200 microseconds 2nd section err-100
MRC:
The time delay of each section of an item.CCDQ
Section Delay Time:
0.400 microseconds 3rd section err-100
MRC:
The time delay of each section of an item.CCDQ
Section Delay Time:
0.800 microseconds 4th section err-100
MRC:
The time delay of each section of an item.CCDQ
Section Delay Time:
0.200 microseconds 2nd section
MRC:
The time delay of each section of an item.CCDQ
Section Delay Time:
0.100 microseconds 1st section
MRC:
The time delay of each section of an item.CCDQ
Section Delay Time:
0.400 microseconds 3rd section
MRC:
The time delay of each section of an item.CCDQ
Section Delay Time:
0.800 microseconds 4th section
MRC:
The change in delay as a result of the temperature change per degree celsius.CCDT
Delay Time Variation Per Deg Celsius:
Not rated
MRC:
The rated time required for the pulse to rise.CCDX
Pulse Rise Time Rating:
Not rated
MRC:
Indicates the type and number of terminals for providing electrical connection.CCFF
Terminal Type And Quantity:
10 solder stud