Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
p30893
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Prefabricated Refrigerator
Κωδικός ονόματος στοιχείου:
19181
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 90.000 inches and 96.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
Between 96.000 inches and 102.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
Between 90.000 inches and 96.000 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
50.0 hertz
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
220.0 volts
MRC:
Indicates the type of unit.APQB
Unit Type:
Prefabricated sectional walk-in
MRC:
Indicates the type of coolant used with the item.ARNA
Coolant Type:
Freon-12 or freon-22 or freon-502
MRC:
The source of power which drives the item.ATJK
Power Source:
Electric motor
MRC:
Indicates the type of condenser.AWLP
Condenser Type:
Any acceptable
MRC:
An indication of whether or not an endless combination feature is included.AYZS
Endless Combination Feature:
Not included
MRC:
Indicates the type of cooling for which the condenser is designed.AZAD
Condenser Cooling Type:
Air
MRC:
Indicates the location of the condenser unit.AZAQ
Condenser Unit Location:
Remote
MRC:
An indication of whether or not refrigerating equipment is included.AZBC
Refrigerating Equipment:
Included
MRC:
Indicates the type of equipment furnished with the item.AZBD
Equipment Type:
Integral mtg
MRC:
An indication of whether or not a stand-by gasoline engine is included.AZBL
Stand-by Gasoline Engine:
Not included
MRC:
An indication of whether or not an opening for portable refrigeration equipment is provided.AZDH
Opening For Portable Refrigeration Equipment:
Not provided
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
Specification Or Standard:
3 size and a style and i type
MRC:
The variation when the item is in conformity with a type designator covered by a specification or standard,except in regard to one or more technical differentiating characteristics.ZZZX
Departure From Cited Designator:
As modified by voltage rating, frequency rating and phase