Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
sp52304
Πληροφορίες ανταλλακτικού
Inavy: transformer, power
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Power Transformer
Κωδικός ονόματος στοιχείου:
32496
MRC:
The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.ABFE
Hazardous Locations/environmental Protection:
Humidity resistant and rainproof and dustproof and corrosion resistant and dripproof and dusttight and salt spray resistant and spraytight and vibration resistant and humidity resistant
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
8.200 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
4.000 inches all mounting facilities all center groupings
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.158 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
8.500 inches
MRC:
A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.ABTD
Mounting Slot Width:
0.280 inches all groupings
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
7.125 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
8.000 inches
MRC:
The distance between mounting facility centers.AEJN
Distance Between Mounting Facility Centers:
4.000 inches all mounting facilities all center groupings
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Boat patrol 36 foot; mrap rg-33
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
4 all groupings
MRC:
The means of attaching the item.AXGY
Mounting Method:
Slot all groupings
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Self-cooled
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
40 amp output current; 4 mounting slots 0.280 inches wide; provides 24v to 12v power conversion for heavy duty applications; under and over voltage protection; reverse voltage protection; voltage transient protection; overload and short circuit protection; thermal overload shutdown; equalization status indicator; protected from the elements
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
3 bus (bar) conductor