Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
t252a155m050ps
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Electrolytic Fixed Capacitor
Κωδικός ονόματος στοιχείου:
00008
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
W/o mtg facilities, axial terminals
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Established
MRC:
The rate of failure determined under specified conditions to establish the reliability of an item,expressed in percent.AARH
Reliability Failure Rate Level In Percent:
0.100
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
1.500 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
0.125 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.250 inches
MRC:
The length of a straight line which passes through the center of a terminal,and terminates at the circumference.AEBT
Terminal Diameter:
0.020 inches
MRC:
The relative level of the quantity of electric charge at a given potential which the capacitor is capable of receiving and storing per section.CQBQ
Capacitance Value Per Section:
1.500 microfarads single section
MRC:
The temperature/s/ at which an item can function without voltage derating.CQJJ
Nonderated Operating Temp:
85.0 degrees celsius
MRC:
The highest value and type of potential that may be continuously applied to the item per section at the highest operating temperature permissible without voltage derating.CQWM
Nonderated Continuous Voltage Rating And Type Per Section:
50.0 dc single section
MRC:
The limits of permissible deviation per section of a measured value from a specified value.CRTP
Tolerance Range Per Section:
-20.00/+20.00 percent single section
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 uninsulated wire lead