Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
tcln-3hw-12x5
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Expansion Valve
Κωδικός ονόματος στοιχείου:
05493
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Brass
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Angle give "adqm" or "adqn" if flanged one or two ends
MRC:
The element, compound,or mixture of which the stem is fabricated,excluding any surface treatment.ABEP
Stem Material:
Brass
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-50.0 degrees fahrenheit
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Refrigerant 22
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Unthreaded external tube
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Plain
MRC:
The length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.ACLH
First End Outside Diameter Tube Accommodated:
0.625 inches
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Not identical
MRC:
A narrative description of the type of end connection.ACLS
Second End Connection Type:
Unthreaded external tube
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACLT
Second End Style Designator:
Plain
MRC:
The length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.ACMP
Second End Outside Diameter Tube Accommodated:
0.500 inches
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Disk, flat
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
Indicates the type of control by which the valve is expanded.AFKK
Valve Expansion Control Type:
Thermostatic
MRC:
A designation of the evaporator temperature range at which the valve is designed to operate.AFKL
Valve Evaporator Tempurature Range Designation:
High
MRC:
Indicates whether the equalizer location is internal,external,or both.AFKU
Valve Equalizer Location:
External
MRC:
The capacity of the item as rated by industry,expressed in british thermal units /btu/ of refrigeration per hour.AGUB
Refrigeration Capacity In Btu Per Hour:
36.0