Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
ts1060bgg
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Teletypewriter Test Set
Κωδικός ονόματος στοιχείου:
03682
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
8.000 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
13.700 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
Between 115.0 volts and 230.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
50.0 hertz
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Unable to decode
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Unable to decode
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Aluminum housing
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Single item w/housing
MRC:
Indicates the type of test for which the item is designed.AQXY
Test Type For Which Designed:
Measures bias and distortion; indicates mechanical defects of teletypewriter keying equipment
MRC:
The testing functions such as range,sensitivity,output,and the like,for which the item is designed.AQXZ
Operating Test Capability:
Range 0 to 50 pct bias, accuracy porm 2 pct, bias and distortion input 60 or 20 ma nuetral, 30 ma polar, 100 ohms and 300 ohms, speed 60, 75 and 100 words per min for teletype and ibm signals, 10.42 unit code, synchronous signals
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The number of alternating current phases.FAAZ
Phase:
Unable to decode
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
8.000 inches
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects a surface.SURF
Surface Treatment:
Any acceptable