Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
type12series90
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Flow Rate Indicating Meter
Κωδικός ονόματος στοιχείου:
38346
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
39.430 inches
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Lubricating oil
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Threaded
MRC:
An indication of whether or not an integral safety device is included.AHZU
Integral Relief Valve:
Not included
MRC:
Indicates the design type of the item.APGF
Design Type:
Case
MRC:
Indicates the type of unit.APQB
Unit Type:
Mounted
MRC:
The number of scales on the item.APSJ
Scale Quantity:
2
MRC:
The structural characteristic of the item.ARQS
Construction:
Inclosed w/sight window
MRC:
A narrative description of the type of outlet connection.ARTH
Outlet Connection Type:
Threaded
MRC:
An indication of the marking(s) on the scale.ASTW
Scale Marking:
Gpm
MRC:
Indicates the type of scale.ATEQ
Scale Type:
Direct capacity reading
MRC:
The number of floats provided.AWAE
Float Quantity:
2
MRC:
The element,compound,or mixture of which the tube is fabricated,excluding any surface treatment.AWGJ
Tube Material:
Glass
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flush panel
MRC:
An indication of whether or not a carrying handle is included.AXQG
Carrying Handle:
Not included
MRC:
The minimum and maximum markings on a dial scale.BHBY
Dial Scale Marking Range:
+0.21/+6.40
MRC:
The minimum and maximum markings on a dial scale.BHBY
Dial Scale Marking Range:
+0.21 to 6.40
MRC:
Designates the size of the outlet connection included on the item.BHCM
Outlet Connection Size:
1-1/4 in. Tube od
MRC:
An indication of whether or not a base(s) is included.BHJT
Base:
Not included
MRC:
Indicates the type of float used.BHSQ
Float Type:
Guided
MRC:
The element,compound,or mixture of which the float is fabricated,excluding any surface treatment.BJDM
Float Material:
Steel, corrosion resisting
MRC:
Indicates the type of guide provided.BMHW
Guide Type:
Beaded tube
MRC:
An indication of whether or not an integral heat source is included.BNHN
Integral Heat Source:
Not included
MRC:
The maximum working pressure at which an item is designed to operate.BPHD
Maximum Working Pressure:
90.0 pounds per square inch
MRC:
Designates the size of the inlet connection included on the item.CPZD
Inlet Connection Size:
1-1/4 in. Tube od
MRC:
The number of metering tubes provided.CPZF
Metering Tube Quantity:
2
MRC:
The smallest increment of graduation on the dial scale.CPZJ
Dial Scale Smallest Increment:
0.001 gpm
MRC:
An indication of whether or not a dial scale reference pointer is included.CPZK
Dial Scale Reference Pointer:
Not included
MRC:
The number of floats in each tube.CPZL
Float Quantity Per Tube:
1
MRC:
An indication of whether or not a spinning float is included.CPZM
Spinning Float:
Not included
MRC:
An indication of whether or not an integral pulsation dampener is included.CPZN
Integral Pulsation Dampener:
Not included
MRC:
The inlet connection position for which the item is designed.CPZP
Inlet Connection Position For Which Designed:
Horizontal
MRC:
Indicates the type of inlet connection device provided.CPZQ
Inlet Connection Device Type:
Stationary
MRC:
The outlet connection position for which the item is designed.CPZR
Outlet Connection Position For Which Designed:
Horizontal
MRC:
Indicates the type of outlet connection device provided.CPZS
Outlet Connection Device Type:
Stationary
MRC:
An indication of whether or not an alarm signal is included.CPZT
Alarm Signal:
Not included
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
Cpzf, awgj, apsj, ateq, ackl, astw, bhby, cpzj, cpzk, w/scales calibrated for mil-l-7808 lube oil at 100 degrees f