Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
wfp2
Πληροφορίες ανταλλακτικού
Usda forest service acceptance specification 5100-00275; pump is supported on water source by a float; flood-proof; automatic float ty throttle; suction hose not required; uses regular gas and oil; throws water stream up to 85 feet; total hd-394 feet; built-in suction screen
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Centrifugal Pump Unit
Κωδικός ονόματος στοιχείου:
17988
MRC:
The number of prime movers incorporated in the unit.AAXH
Prime Mover Quantity:
1
MRC:
The cooling medium used to maintain the required operating temperature of the prime mover.AAXS
Prime Mover Cooling Medium:
Air
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Skid
MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
1
MRC:
The number of intake connections included on the item.AAYT
Intake Connection Quantity:
1
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
1
MRC:
Indicates the type of discharge connection included on the item.AAYW
Discharge Connection Type:
Threaded external
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Water, fresh
MRC:
The number of pumps incorporated in the item.AENC
Pump Quantity:
1
MRC:
The maximum rated capacity delivered by the item.AHYV
Maximum Discharge Flow Rate:
60.0 gallons per minute
MRC:
The pressure of the media delivered by the item at maximum rated discharge capacity.AHYW
Discharge Pressure:
171.0 pounds per square inch gage
MRC:
The position in which the pumping element/s/ is designed to operate.AHZA
Pumping Element Operating Position:
Vertical
MRC:
The design of a centrifugal pump as determined by the direction of media flow with respect to the axis of the shaft.AHZE
Centrifugal Pump Design:
Mixed flow
MRC:
The number of impellers incorporated in the centrifugal pump.AHZF
Centrifugal Pump Impeller Quantity:
1
MRC:
Indicates the type of suction produced by the impeller of the centrifugal pump.AHZG
Centrifugal Pump Impeller Suction Type:
Single
MRC:
A measurement of the longest dimension of an item unencumbered by packaging or packing,in distinction from width.AJAF
Unpackaged Unit Length:
28.000 inches
MRC:
A measurement taken at right angles to the length of an item unencumbered by packaging or packing,in distinction from thickness.AJAG
Unpackaged Unit Width:
20.0000 inches
MRC:
A measurement from the bottom to the top of an item unencumbered by packaging or packing,in distinction from depth.AJAH
Unpackaged Unit Height:
16.000 inches
MRC:
The element,compound,or mixture of the basic material of which the major portion of the pump is fabricated.AJAL
Pump Basic Material:
Aluminum
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Gasoline engine
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the discharge connection.ASAZ
Discharge Connection Thread Size And Series/type Designator:
1.500-9 nh
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Self-priming
MRC:
The rated power of the prime mover.CSYL
Prime Mover Power Rating:
8.000 horsepower